The value of tmnxOamBierPingCtlBfrIdStart specifies the start of a
contiguous range of Bit-Forwarding Router (BFR) identifiers to be
pinged. tmnxOamBierPingCtlBfrIdEnd specifies the end of the range.
Each BFR-ID in the range must be a member of the tested sub-domain
(as configured using tmnxOamBierPingCtlSubDomain). Otherwise, the
test will fail.
Zero indicates no start for the BFR-ID range has been configured.
The following objects must be set together in one SNMP Set PDU:
tmnxOamBierPingCtlBfrIdStart,
tmnxOamBierPingCtlBfrIdEnd.
There are three methods to configure the destination(s) to be pinged:
1. tmnxOamBierPingCtlBfrId.
2. tmnxOamBierPingCtlBfrIdStart, tmnxOamBierPingCtlBfrIdEnd.
3. tmnxOamBierPingBfrPfxCtlAddrType, tmnxOamBierPingBfrPfxCtlAddress.
Exactly one of the methods must be used. Otherwise, the test will
fail.
Context
- MIB
- TIMETRA-OAM-TEST-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.11.1.31.1.3- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tmnxOamBierPingCtlEntry
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-4096