tmnxSrrpOperMasterDownTimer
TIMETRA-MC-REDUNDANCY-MIB ·
.1.3.6.1.4.1.6527.3.1.2.40.1.9.1.19
Object
The value of tmnxSrrpOperMasterDownTimer indicates the current value
of the Master Down Timer.
When a backup router receives an SRRP advertisement from a master, it
resets this timer to the value of the Master Down Interval and begins
to count down. If the backup router does not receive an advertisement
till this timer times out, it will assume that the master is down and
will declare itself to be the master.
Context
- MIB
- TIMETRA-MC-REDUNDANCY-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.40.1.9.1.19- Type
- column
- Access
- readonly
- Status
- current
- Units
- milliseconds
- Parent
- tmnxSrrpOperEntry
Syntax
milliseconds SNMPv2-TCTimeInterval
Values & Constraints
No enumerated values or constraints recorded.