vRtrIsisReferenceBw
TIMETRA-ISIS-MIB ·
.1.3.6.1.4.1.6527.3.1.2.10.1.1.1.13
Object
Reference bandwidth - In order to calculate the lowest cost
to reach a given destination each configured level on each
interface must have a cost. If the reference-bandwidth is
defined then the cost is calculated using the following
formula:
Cost = reference-bandwidth / bandwidth.
If the reference bandwidth is configured as Ten Gig
(10,000,000,000) a 100-Mbps interface has a default metric of
100. In order for metrics in excess of 63 to be configured
wide metrics must be deployed.
A value of '0' means that the reference bandwidth is not defined.
Context
- MIB
- TIMETRA-ISIS-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.10.1.1.1.13- Type
- column
- Access
- readonly
- Status
- obsolete
- Units
- kilobps
- Parent
- vRtrIsisEntry
Syntax
kilobps TIMETRA-TC-MIBTmnxReferenceBandwidth
Values & Constraints