tmnxDot1agCfmMepTxLbmInterval
TIMETRA-IEEE8021-CFM-MIB ·
.1.3.6.1.4.1.6527.3.1.2.52.7.1.1.40
Object
column
r/w
deciseconds Unsigned32
The value of tmnxDot1agCfmMepTxLbmInterval specifies the duration, in deciseconds, between loopback PDU transmissions. A value of zero is only valid if there are 5 or fewer loopbacks in the test (as defined by dot1agCfmMepTransmitLbmMessages).
Context
- MIB
- TIMETRA-IEEE8021-CFM-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.52.7.1.1.40- Type
- column
- Access
- readwrite
- Status
- current
- Units
- deciseconds
- Parent
- tmnxDot1agCfmMepEntry
Syntax
deciseconds Unsigned32
Values & Constraints
Object Constraints
range: 0-600