tmnxDot1agCfmMepCollectLmmStats
TIMETRA-IEEE8021-CFM-MIB ·
.1.3.6.1.4.1.6527.3.1.2.52.7.1.1.44
Object
The value of tmnxDot1agCfmMepCollectLmmStats specifies whether or not
to compute the Y.1731 Ethernet Loss Measurement (ETH-LM) RxFCl and
TxFCl service frame counters for the specified MEP. Note that when
tmnxDot1agCfmMepCollectLmmStats is set to 'true', all data traffic
regardless of forwarding class level, both in and out of profile, will
be aggregated to a single stat counter.
Configuration of tmnxDot1agCfmMepCollectLmmStats is mutually exclusive
with the forwarding class level aware objects
tmnxDot1agCfmMepCollLmmFcSts and tmnxDot1agCfmMepCollLmmFcStsInP.
The RxFCl and TxFCl counters are used by ETH-LM tests. An ETH-LM test
is created using TIMETRA-OAM-PM-MIB::tmnxOamPmCfgLossLmmRowStatus.
Context
- MIB
- TIMETRA-IEEE8021-CFM-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.52.7.1.1.44- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- tmnxDot1agCfmMepEntry
Syntax
SNMPv2-TCTruthValue
Values & Constraints
No enumerated values or constraints recorded.