tIPFilterParamsExtStickyDst
TIMETRA-FILTER-MIB ·
.1.3.6.1.4.1.6527.3.1.2.21.53.1.15
Object
column
r/w
seconds Integer32
The value of the object tIPFilterParamsExtStickyDst specifies how long
the system will wait (in seconds) until it activates the best action
(action with available PBR/PBF destination and the highest priority).
Until then the action specified by tIPFilterParamsExtPbrDwnActOvr will
be taken on a packet matching the filter entry. After the value of the
active destination is fixed it will remain unchanged until the active
PBR/PBF destination becomes unreachable.
The value of -1 indicates that the property of PBR destination
stickiness is turned off. When the property of stickiness is turned
off the active PBR/PBF destination is always the one which is
available and has the highest priority.
The countdown starts when there was no PBR/PBF destination reachable
and any PBR/PBF destination becomes reachable.
tIPFilterParamsExtStickyDst can be set to value other than -1 only if
the value of tIPvXFltrEntryActAction is one of following values:
- forwardSap
- forwardSdp
- forwardNextHopRtr
Context
- MIB
- TIMETRA-FILTER-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.21.53.1.15- Type
- column
- Access
- readwrite
- Status
- current
- Units
- seconds
- Parent
- tIPFilterParamsExtEntry
Syntax
seconds Integer32
Values & Constraints
Object Constraints
range: -1-65535