tmnxPhysChassPowerSupDCStatus
TIMETRA-CHASSIS-MIB ·
.1.3.6.1.4.1.6527.3.1.2.2.1.24.2.1.3
Object
column TmnxDeviceState
The value of tmnxPhysChassPowerSupDCStatus indicates the DC status of
the power supply in the physical chassis.
If the value is 'deviceStateOk (3)', the output DC voltage is within
range. If the value is 'deviceStateFailed (4)', a DC voltage out of
range condition has been detected. A value of 'deviceNotEquipped (2)'
indicates that the DC power supply is not present or the equipped
power supply does not support the reporting of this status.
Context
- MIB
- TIMETRA-CHASSIS-MIB
- OID
.1.3.6.1.4.1.6527.3.1.2.2.1.24.2.1.3- Type
- column
- Access
- readonly
- Status
- current
- Parent
- tmnxPhysChassisPowerSupplyEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'TIMETRA-CHASSIS-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-CHASSIS-MIB::tmnxPhysChassPowerSupDCStatus'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'TIMETRA-CHASSIS-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'TIMETRA-CHASSIS-MIB::tmnxPhysChassPowerSupDCStatus.<tmnxPhysChassisClass>.<tmnxPhysChassisNum>.<tmnxPhysChassPowerSupId>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'TIMETRA-CHASSIS-MIB' -M '/opt/observium/mibs/nokia:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'TIMETRA-CHASSIS-MIB::tmnxPhysChassPowerSupDCStatus'
Syntax
- Source
- TmnxDeviceState
- Base type
Enumeration
Values & Constraints
Type Values
1 | deviceStateUnknown |
2 | deviceNotEquipped |
3 | deviceStateOk |
4 | deviceStateFailed |
5 | deviceStateOutOfService |
6 | deviceNotProvisioned |
7 | deviceNotApplicable |
Conformance
Member of