tmnxMDAFailOnError

TIMETRA-CHASSIS-MIB · .1.3.6.1.4.1.6527.3.1.2.2.3.8.1.49

Object

column r/w Bits
The value of tmnxMDAFailOnError specifies the set of events that, if
triggered, will cause the MDA to fail. The suppression or generation
of the NOTIFICATION-TYPE event is independent of the MDA failing.
              
The following set of events are configurable:
     eventGroupA (0) - tmnxEqMdaXplError
                     - tmnxEqMdaIngrXplError
              
If an XPL error is declared, the MDA is declared failed.

Context

MIB
TIMETRA-CHASSIS-MIB
OID
.1.3.6.1.4.1.6527.3.1.2.2.3.8.1.49
Type
column
Access
readwrite
Status
current
Parent
tmnxMDAEntry
Table
tmnxMDATable
Siblings
56

Syntax

Bits

Values & Constraints

Enumerated Values
0eventGroupA

Related Objects

Sibling Objects