t11FcSpSaIfStorageType
T11-FC-SP-SA-MIB ·
.1.3.6.1.2.1.179.1.1.1.1.7
Object
This object specifies the memory realization of
information related to FC-SP Security Associations
for interface(s) to a particular Fabric; specifically,
for rows created and/or modified in these tables:
t11FcSpSaPropTable
t11FcSpSaTSelDrByTable
t11FcSpSaControlTable
and, for modified information contained in the same
row as an instance of this object.
Even if an instance of this object has the value
'permanent(4)', none of the information defined in
this MIB module for interface(s) to the given Fabric
need to be writable.
Context
- MIB
- T11-FC-SP-SA-MIB
- OID
.1.3.6.1.2.1.179.1.1.1.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- t11FcSpSaIfEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'T11-FC-SP-SA-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'T11-FC-SP-SA-MIB::t11FcSpSaIfStorageType'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'T11-FC-SP-SA-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'T11-FC-SP-SA-MIB::t11FcSpSaIfStorageType.<fcmInstanceIndex>.<t11FcSpSaIfIndex>.<t11FcSpSaIfFabricIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'T11-FC-SP-SA-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'T11-FC-SP-SA-MIB::t11FcSpSaIfStorageType'
Syntax
- Source
- SNMPv2-TCStorageType
- Base type
Enumeration
Type Description
Describes the memory realization of a conceptual row. A
row which is volatile(2) is lost upon reboot. A row which
is either nonVolatile(3), permanent(4) or readOnly(5), is
backed up by stable storage. A row which is permanent(4)
can be changed but not deleted. A row which is readOnly(5)
cannot be changed nor deleted.
If the value of an object with this syntax is either
permanent(4) or readOnly(5), it cannot be written.
Conversely, if the value is either other(1), volatile(2) or
nonVolatile(3), it cannot be modified to be permanent(4) or
readOnly(5). (All illegal modifications result in a
'wrongValue' error.)
Every usage of this textual convention is required to
specify the columnar objects which a permanent(4) row must
at a minimum allow to be writable.
Values & Constraints
Type Values
1 | other |
2 | volatile |
3 | nonVolatile |
4 | permanent |
5 | readOnly |
Conformance
Member of
Compliance refinements
t11FcSpSaMIBCompliance
readonly
Write access is not required.