ccRapPollSymbolMusInterval

SYMBOL-CC-WS2000-MIB · .1.3.6.1.4.1.388.11.2.7.1.3.2

Object

scalar r/w minutesSNMPv2-SMIInteger32
Amount of time to wait before polling the same MU
for its known AP list again.
          
Assuming the MU is disrupted for 3sec when it is
polled, a value of 5min or more would interrupt MUs
less than 1% of the time.
          
The state of this variable persists across reboots.
The factory-default state is 10 (minutes).

Context

MIB
SYMBOL-CC-WS2000-MIB
OID
.1.3.6.1.4.1.388.11.2.7.1.3.2
Type
scalar
Access
readwrite
Status
current
Units
minutes
Parent
ccRapControlPollSymbolMus
Groups
1

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance