fsofcTraceEnable
SUPERMICRO-OFC-CFG-MIB ·
.1.3.6.1.4.1.10876.101.2.81.1.1.1.8
Object
column
r/w
Unsigned32
This object can be used to enable trace dynamically in OFC
module. A four byte integer value is specified for enabling
the level of tracing.Each Bit in the four byte integer variable
represents a level of Trace.
Trace Levels
BIT
0 - Init and Shutdown traces
1 - Management traces
2 - Data Path traces
3 - Control Plane traces
4 - Packet Dump traces
5 - Traces related to all resources except buffers
6 - All Failure traces
7 - Buffer allocation/release traces
The remaining bits are unused. The combination of levels are also allowed.
For example if the bits 1 and 2 are set, then the Trace statements related to
management and Data Path will be printed.
The user have to enter the corresponding integer value for the bits set.
For example if bits 1 and 2 are set then value of 6 should be entered.
Context
- MIB
- SUPERMICRO-OFC-CFG-MIB
- OID
.1.3.6.1.4.1.10876.101.2.81.1.1.1.8- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- fsofcCfgEntry
Syntax
Unsigned32
Values & Constraints
No enumerated values or constraints recorded.