fsErpsRingRplPort

SUPERMICRO-ERPS-MIB · .1.3.6.1.4.1.10876.101.2.40.2.1.1.6

Object

This object identifies the RPL port of the ring. 
              
Valid values for this object are '0', 'IfIndex of fsErpsRingPort1' and 
'IfIndex of fsErpsRingPort2'. 
              
When a port is configured as a RPL port,  that node becomes RPL 
owner for that ring.
              
Value '0' indicates that none of the ring ports is a RPL port
and hence the node is not a RPL owner.
              
In an interconnected node of a sub-ring, the 'fsErpsRingPort1' alone 
can be chosen as an RPL port when administrator decides to have the 
interconnected node as the RPL Owner of the sub-ring.
              
Administrator has to ensure that, only one node in a ring is 
configured as RPL owner.

Context

MIB
SUPERMICRO-ERPS-MIB
OID
.1.3.6.1.4.1.10876.101.2.40.2.1.1.6
Type
column
Access
readwrite
Status
current
Parent
fsErpsRingEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SUPERMICRO-ERPS-MIB' -M '/opt/observium/mibs/supermicro:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SUPERMICRO-ERPS-MIB::fsErpsRingRplPort'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SUPERMICRO-ERPS-MIB' -M '/opt/observium/mibs/supermicro:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SUPERMICRO-ERPS-MIB::fsErpsRingRplPort.<fsErpsContextId>.<fsErpsRingId>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SUPERMICRO-ERPS-MIB' -M '/opt/observium/mibs/supermicro:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SUPERMICRO-ERPS-MIB::fsErpsRingRplPort'

Syntax

Source
IF-MIBInterfaceIndexOrZero
Base type
Integer32
Display format
d
Type Description
This textual convention is an extension of the
InterfaceIndex convention.  The latter defines a greater
than zero value used to identify an interface or interface
sub-layer in the managed system.  This extension permits the
additional value of zero.  the value zero is object-specific
and must therefore be defined as part of the description of
any object which uses this syntax.  Examples of the usage of
zero might include situations where interface was unknown,
or when none or all interfaces need to be referenced.

Values & Constraints

Type Constraints
range: 0..2147483647