cntpTimeMode
SONOMA-MIB ·
.1.3.6.1.4.1.13827.11.1.19
Object
scalar SNMPv2-TCDisplayString
This is an ASCII string showing the time mode of operation for any
optional IRIG timecode outputs or the optional front panel vacuum
fluorescent display. It DOES NOT indicate the time mode of the Linux
OS clock or the NTP sub-system. Both of these are ALWAYS UTC.
It can be LOCAL_AUTO, LOCAL_MANUAL, GPS or UTC. In LOCAL_AUTO mode,
the local offset to UTC is automatically determined from the CDMA
transmissions received from the base station. In LOCAL_MANUAL mode,
the local offset to UTC is user programmed and overrides the CDMA
system data.
Context
- MIB
- SONOMA-MIB
- OID
.1.3.6.1.4.1.13827.11.1.19- Type
- scalar
- Access
- readonly
- Status
- current
- Parent
- cntp
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SONOMA-MIB' -M '/opt/observium/mibs/endrun:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SONOMA-MIB::cntpTimeMode.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SONOMA-MIB' -M '/opt/observium/mibs/endrun:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SONOMA-MIB::cntpTimeMode'
Syntax
- Source
- SNMPv2-TCDisplayString
- Base type
OctetString- Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as
US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special
meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the
same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is
illegal. (Note that this also means that a string may
end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255
characters in length.
Values & Constraints
Object Constraints
range: 0-8
Type Constraints
range: 0..255