sonetMediumValidIntervals
SONET-MIB ·
.1.3.6.1.2.1.10.39.1.1.1.1.3
Object
column
Integer32
The number of previous 15-minute intervals for which data was collected. A SONET/SDH interface must be capable of supporting at least n intervals. The minimum value of n is 4. The default of n is 32. The maximum value of n is 96. The value will be <n> unless the measurement was (re-)started within the last (<n>*15) minutes, in which case the value will be the number of complete 15 minute intervals for which the agent has at least some data. In certain cases (e.g., in the case where the agent is a proxy) it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available.
Context
- MIB
- SONET-MIB
- OID
.1.3.6.1.2.1.10.39.1.1.1.1.3- Type
- column
- Access
- readonly
- Status
- current
- Parent
- sonetMediumEntry
- Table
- sonetMediumTable
- Siblings
- 7
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-96
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sonetMediumType This variable identifies whether a SONET
or a SDH signal is used across this interface. | column | Enumeration | .1.3.6.1.2.1.10.39.1.1.1.1.1 |
| sonetMediumTimeElapsed The number of seconds, including partial seconds,
that have elapsed since the beginning of the current
measurement period. If, for some reason, such as an
adjustment in the system… | column | Integer32 | .1.3.6.1.2.1.10.39.1.1.1.1.2 |
| sonetMediumLineCoding This variable describes the line coding for
this interface. The B3ZS and CMI are used for
electrical SONET/SDH signals (STS-1 and STS-3).
The Non-Return to Zero (NRZ) and the Retu… | column | Enumeration | .1.3.6.1.2.1.10.39.1.1.1.1.4 |
| sonetMediumLineType This variable describes the line type for
this interface. The line types are
Short and Long Range
Single Mode fiber or Multi-Mode fiber interfaces,
and coax and UTP for electrical… | column | Enumeration | .1.3.6.1.2.1.10.39.1.1.1.1.5 |
| sonetMediumCircuitIdentifier This variable contains the transmission
vendor's circuit identifier, for the
purpose of facilitating troubleshooting.
Note that the circuit identifier, if available,
is also repre… | column | OctetString | .1.3.6.1.2.1.10.39.1.1.1.1.6 |
| sonetMediumInvalidIntervals The number of intervals in the range from
0 to sonetMediumValidIntervals for which no
data is available. This object will typically
be zero except in cases where the data for some… | column | Integer32 | .1.3.6.1.2.1.10.39.1.1.1.1.7 |
| sonetMediumLoopbackConfig The current loopback state of the SONET/SDH interface. The
values mean:
sonetNoLoop
Not in the loopback state. A device that is not
capable of performi… | column | Bits | .1.3.6.1.2.1.10.39.1.1.1.1.8 |