sonetMediumLoopbackConfig
SONET-MIB ·
.1.3.6.1.2.1.10.39.1.1.1.1.8
Object
column
r/w
Bits
The current loopback state of the SONET/SDH interface. The
values mean:
sonetNoLoop
Not in the loopback state. A device that is not
capable of performing a loopback on this interface
shall always return this value.
sonetFacilityLoop
The received signal at this interface is looped back
out through the corresponding transmitter in the return
direction.
sonetTerminalLoop
The signal that is about to be transmitted is connected
to the associated incoming receiver.
sonetOtherLoop
Loopbacks that are not defined here.
Context
- MIB
- SONET-MIB
- OID
.1.3.6.1.2.1.10.39.1.1.1.1.8- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- sonetMediumEntry
- Table
- sonetMediumTable
- Siblings
- 7
Syntax
Bits
Values & Constraints
Enumerated Values
0 | sonetNoLoop |
1 | sonetFacilityLoop |
2 | sonetTerminalLoop |
3 | sonetOtherLoop |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| sonetMediumType This variable identifies whether a SONET
or a SDH signal is used across this interface. | column | Enumeration | .1.3.6.1.2.1.10.39.1.1.1.1.1 |
| sonetMediumTimeElapsed The number of seconds, including partial seconds,
that have elapsed since the beginning of the current
measurement period. If, for some reason, such as an
adjustment in the system… | column | Integer32 | .1.3.6.1.2.1.10.39.1.1.1.1.2 |
| sonetMediumValidIntervals The number of previous 15-minute intervals
for which data was collected.
A SONET/SDH interface must be capable
of supporting at least n intervals.
The minimum value of n is 4.
The… | column | Integer32 | .1.3.6.1.2.1.10.39.1.1.1.1.3 |
| sonetMediumLineCoding This variable describes the line coding for
this interface. The B3ZS and CMI are used for
electrical SONET/SDH signals (STS-1 and STS-3).
The Non-Return to Zero (NRZ) and the Retu… | column | Enumeration | .1.3.6.1.2.1.10.39.1.1.1.1.4 |
| sonetMediumLineType This variable describes the line type for
this interface. The line types are
Short and Long Range
Single Mode fiber or Multi-Mode fiber interfaces,
and coax and UTP for electrical… | column | Enumeration | .1.3.6.1.2.1.10.39.1.1.1.1.5 |
| sonetMediumCircuitIdentifier This variable contains the transmission
vendor's circuit identifier, for the
purpose of facilitating troubleshooting.
Note that the circuit identifier, if available,
is also repre… | column | OctetString | .1.3.6.1.2.1.10.39.1.1.1.1.6 |
| sonetMediumInvalidIntervals The number of intervals in the range from
0 to sonetMediumValidIntervals for which no
data is available. This object will typically
be zero except in cases where the data for some… | column | Integer32 | .1.3.6.1.2.1.10.39.1.1.1.1.7 |