rptrMonitorPortSymbolErrors

SNMP-REPEATER-MIB · .1.3.6.1.2.1.22.2.3.2.1.2

Object

This counter is incremented by one each time when
              
valid length packet was received at the port and
there was at least one occurrence of an invalid
data symbol. This can increment only once per valid
carrier event. A collision presence at any port of
the repeater containing port N, will not cause this
attribute to increment.
              
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes.
              
The approximate minimum time for rollover of this
counter is 7.4 hours at 100Mb/s.

Context

MIB
SNMP-REPEATER-MIB
OID
.1.3.6.1.2.1.22.2.3.2.1.2
Type
column
Access
readonly
Status
current
Parent
rptrMonitor100PortEntry
Groups
1

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SNMP-REPEATER-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SNMP-REPEATER-MIB::rptrMonitorPortSymbolErrors'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SNMP-REPEATER-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SNMP-REPEATER-MIB::rptrMonitorPortSymbolErrors.<rptrMonitorPortGroupIndex>.<rptrMonitorPortIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SNMP-REPEATER-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SNMP-REPEATER-MIB::rptrMonitorPortSymbolErrors'

Syntax

Source
SNMPv2-SMICounter32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Conformance