rptrMonitorPortAlignmentErrors

SNMP-REPEATER-MIB · .1.3.6.1.2.1.22.2.3.1.1.6

Object

column SNMPv2-SMICounter32
This counter is incremented by one for each frame
received on this port with the FCSError and
FramingError signals asserted and CollisionEvent
signal deasserted and whose OctetCount is greater
than or equal to minFrameSize and less than or
equal to maxFrameSize (Ref: IEEE 802.3 Std,
4.4.2.1).  If rptrMonitorPortAlignmentErrors is
incremented then the rptrMonitorPortFCSErrors
Counter shall not be incremented for the same
frame.
              
A discontinuity may occur in the value
when the value of object
rptrMonitorPortLastChange changes.
              
The approximate minimum time for rollover of this
counter is 80 hours at 10Mb/s.

Context

MIB
SNMP-REPEATER-MIB
OID
.1.3.6.1.2.1.22.2.3.1.1.6
Type
column
Access
readonly
Status
current
Parent
rptrMonitorPortEntry
Table
rptrMonitorPortTable
Siblings
15

Syntax

SNMPv2-SMICounter32
Source
SNMPv2-SMICounter32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Related Objects

Sibling Objects