rptrAddrTrackSourceAddrChanges
SNMP-REPEATER-MIB ·
.1.3.6.1.2.1.22.3.3.1.1.4
Object
column SNMPv2-SMICounter32
This counter is incremented by one for each time
that the rptrAddrTrackLastSourceAddress attribute
for this port has changed.
This may indicate whether a link is connected to a
single DTE or another multi-user segment.
A discontinuity may occur in the value when the
value of object rptrMonitorPortLastChange changes.
The approximate minimum time for rollover of this
counter is 81 hours in a 10Mb/s repeater.
Context
- MIB
- SNMP-REPEATER-MIB
- OID
.1.3.6.1.2.1.22.3.3.1.1.4- Type
- column
- Access
- readonly
- Status
- current
- Parent
- rptrAddrTrackEntry
- Groups
- 3
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SNMP-REPEATER-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SNMP-REPEATER-MIB::rptrAddrTrackSourceAddrChanges'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SNMP-REPEATER-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SNMP-REPEATER-MIB::rptrAddrTrackSourceAddrChanges.<rptrAddrTrackGroupIndex>.<rptrAddrTrackPortIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SNMP-REPEATER-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SNMP-REPEATER-MIB::rptrAddrTrackSourceAddrChanges'
Syntax
- Source
- SNMPv2-SMICounter32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295