sleRedControlFaultTimeout
SLE-RED-MIB ·
.1.3.6.1.4.1.6296.101.22.1.2.9
Object
scalar
r/w
Integer32
Healthcheck timeout. If a software module doesn't respond for the given time,
it is regarded as a timed-out module.
(Unit: second, default is '5')
Context
- MIB
- SLE-RED-MIB
- OID
.1.3.6.1.4.1.6296.101.22.1.2.9- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- sleRedControl
Syntax
Integer32
Values & Constraints
Object Constraints
range: 5-720000