slSonetConfigSfThreshold
SL-SONET-MIB ·
.1.3.6.1.4.1.4515.1.6.1.1.1.7
Object
column r/w
Integer32
This object contains the Bit Error Rate threshold for Signal Fault detection on the working line. Once this threshold is exceeded, an APS switch will occur. This value is 10 to the -n, where n is between 3 and 5. (read-write)
Context
- MIB
- SL-SONET-MIB
- OID
.1.3.6.1.4.1.4515.1.6.1.1.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- slSonetConfigEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SL-SONET-MIB' -M '/opt/observium/mibs/packetlight:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SL-SONET-MIB::slSonetConfigSfThreshold'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SL-SONET-MIB' -M '/opt/observium/mibs/packetlight:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SL-SONET-MIB::slSonetConfigSfThreshold.<ifIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SL-SONET-MIB' -M '/opt/observium/mibs/packetlight:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SL-SONET-MIB::slSonetConfigSfThreshold'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 3-5