sfpDiagTxBias
SL-SFP-MIB ·
.1.3.6.1.4.1.4515.1.10.2.1.1.36
Object
column Integer32
Internally measured TX Bias Current. The value 0 means 0 Volt. An increment on one is equivalent to 2 uA, yielding a total range of 0 to 131 mA. Accuracy is vendor specific but must be better than ?3dB over specified temperature and voltage. Data is not valid when the transmitter is disabled.
Context
- MIB
- SL-SFP-MIB
- OID
.1.3.6.1.4.1.4515.1.10.2.1.1.36- Type
- column
- Access
- readonly
- Status
- current
- Parent
- sfpDiagEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SL-SFP-MIB' -M '/opt/observium/mibs/packetlight:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SL-SFP-MIB::sfpDiagTxBias'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SL-SFP-MIB' -M '/opt/observium/mibs/packetlight:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SL-SFP-MIB::sfpDiagTxBias.<sfpDiagInterface>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SL-SFP-MIB' -M '/opt/observium/mibs/packetlight:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SL-SFP-MIB::sfpDiagTxBias'
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-65535