optApsConfigWaitToRestore
SL-OPT-APS-MIB ·
.1.3.6.1.4.1.4515.1.11.1.1.1.10
Object
column
r/w
minutes Unsigned32
This object contains interval in minutes to wait before attempting to switch back to working connection. Not applicable if the connection is configured in non-revertive mode, i.e. protection connection will continue to be active, even if failures on the working connection are cleared. The framer clears the signal-fault and signal-degrade when APS switch occurs. Please refer to 'optApsRevertive' for description of non-revertive (read-write).
Context
- MIB
- SL-OPT-APS-MIB
- OID
.1.3.6.1.4.1.4515.1.11.1.1.1.10- Type
- column
- Access
- readwrite
- Status
- current
- Units
- minutes
- Parent
- optApsConfigEntry
Syntax
minutes Unsigned32
Values & Constraints
Object Constraints
range: 1-12