esPointClassValueStr
SITEBOSS-530-STD-MIB ·
.1.3.6.1.4.1.3052.12.1.1.1.1.11
Object
column SNMPv2-TCDisplayString
For CC inputs, this is the CC active/inactive class setting
setting value that currently corresponds to the event state.
So if the CC input is in the event state, then this object
is the active class setting value. If the CC input is in the
normal state, then this object is the inactive class setting
value.
For relay/power, analog and temp outputs, this is the output
class string given the event (Very High, High, Normal, Low and
Very Low). The class string is based upon the chosen string in
the class table for e.g. Info, Minor, Major, Minor, Critical etc.
If the given event is High, the chosen Class string for this event
is what returned.
Context
- MIB
- SITEBOSS-530-STD-MIB
- OID
.1.3.6.1.4.1.3052.12.1.1.1.1.11- Type
- column
- Access
- readonly
- Status
- current
- Parent
- esPointEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SITEBOSS-530-STD-MIB' -M '/opt/observium/mibs/asentria:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SITEBOSS-530-STD-MIB::esPointClassValueStr'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SITEBOSS-530-STD-MIB' -M '/opt/observium/mibs/asentria:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SITEBOSS-530-STD-MIB::esPointClassValueStr.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SITEBOSS-530-STD-MIB' -M '/opt/observium/mibs/asentria:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SITEBOSS-530-STD-MIB::esPointClassValueStr'
Syntax
- Source
- SNMPv2-TCDisplayString
- Base type
OctetString- Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as
US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special
meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the
same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is
illegal. (Note that this also means that a string may
end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255
characters in length.
Values & Constraints
Enumerated Values
0 | disable |
1 | enable |
Type Constraints
range: 0..255