ptpClockDomainIndex
SIAE-PTP-MIB ·
.1.3.6.1.4.1.3373.1103.100.4.1.1.1
Object
column ClockDomainType
This object specifies the domain number used to create logical group of PTP devices. The Clock Domain is a logical group of clocks and devices that synchronize with each other using the PTP protocol.
Context
- MIB
- SIAE-PTP-MIB
- OID
.1.3.6.1.4.1.3373.1103.100.4.1.1.1- Type
- column
- Access
- readonly
- Status
- current
- Parent
- ptpClockDataSetEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'SIAE-PTP-MIB' -M '/opt/observium/mibs/siaemic:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SIAE-PTP-MIB::ptpClockDomainIndex'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'SIAE-PTP-MIB' -M '/opt/observium/mibs/siaemic:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'SIAE-PTP-MIB::ptpClockDomainIndex.<ptpClockDomainIndex>.<ptpClockTypeIndex>.<ptpClockInstanceIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'SIAE-PTP-MIB' -M '/opt/observium/mibs/siaemic:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'SIAE-PTP-MIB::ptpClockDomainIndex'
Syntax
- Source
- ClockDomainType
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 24..43