rcSfpDdmPollingInterval
RUGGEDCOM-SFP-DDM-MIB ·
.1.3.6.1.4.1.15004.4.17.1.1
Object
scalar r/w
minutesInteger32
The time interval in minutes to wait between two consecutive readings from SFP/SFP+ transceivers installed. When this interval is set to 0, the SFP DDM feature will be disabled on the system.
Context
- MIB
- RUGGEDCOM-SFP-DDM-MIB
- OID
.1.3.6.1.4.1.15004.4.17.1.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- minutes
- Parent
- rcSfpDdmGlobalConfig
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RUGGEDCOM-SFP-DDM-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RUGGEDCOM-SFP-DDM-MIB::rcSfpDdmPollingInterval.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RUGGEDCOM-SFP-DDM-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RUGGEDCOM-SFP-DDM-MIB::rcSfpDdmPollingInterval'
Syntax
minutesInteger32
Values & Constraints
Object Constraints
range: 0-30
Conformance
Member of