rcPTP1588BClkSyncInt
RUGGEDCOM-PTP1588-MIB ·
.1.3.6.1.4.1.15004.4.12.4.1.1.8
Object
column r/w
Enumeration
The PTP (Precision Time Protocol) Sync interval (mean time interval between successive Sync messages). Interpretation placed on the value: 1: Sync interval value is 125 Millisecond. 2: Sync interval value is 250 Millisecond. 3: Sync interval value is 500 Millisecond. 4: Sync interval value is 1 Second. 5: Sync interval value is 2 Second.
Context
- MIB
- RUGGEDCOM-PTP1588-MIB
- OID
.1.3.6.1.4.1.15004.4.12.4.1.1.8- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- rcPTP1588BClkEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RUGGEDCOM-PTP1588-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RUGGEDCOM-PTP1588-MIB::rcPTP1588BClkSyncInt'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RUGGEDCOM-PTP1588-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RUGGEDCOM-PTP1588-MIB::rcPTP1588BClkSyncInt.<rcPTP1588BClkPorts>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RUGGEDCOM-PTP1588-MIB' -M '/opt/observium/mibs/siemens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RUGGEDCOM-PTP1588-MIB::rcPTP1588BClkSyncInt'
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | value125millSec |
2 | value250millSec |
3 | value500millSec |
4 | value1Sec |
5 | value2Sec |
Conformance
Member of