redundancyCircuitMACAddrDel

REPEATER-MIB-2 · .1.3.6.1.4.1.52.1.2.1.8.12

Object

scalar mandatory r/w OctetString
A get will return a null string.
A set deletes an ethernet address from the polling list for the
indicated circuit.

Context

MIB
REPEATER-MIB-2
OID
.1.3.6.1.4.1.52.1.2.1.8.12
Type
scalar
Access
readwrite
Status
mandatory
Parent
redundancy

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'REPEATER-MIB-2' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'REPEATER-MIB-2::redundancyCircuitMACAddrDel.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'REPEATER-MIB-2' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'REPEATER-MIB-2::redundancyCircuitMACAddrDel'

Syntax

OctetString

Values & Constraints