rcftSlotLBKTestOk

RAISECOM-RCFT-MIB · .1.3.6.1.4.1.8886.2.1.5.1.1.29

Object

column Enumeration
??ģ???ڻ??ز???ִ?н??(1:?ɹ?,2:ʧ??). 
?????ͻ????????,ͨ???쿴?ö????״̬?жϻ???????ִ?еĽ??
The value of this object show the result of the loop test. 
After sending the order by setting the object of the rcftSlotOrder to 1 
two thing should be done:
first -- judge whether the mcu excute the instruction throug the value 
of the rcftSlotLBKTest above.
secondly -- if the condition above is true then judge the result of the 
loop test throug the value of this object:
1: loop test ok
2: loop test fault

Context

MIB
RAISECOM-RCFT-MIB
OID
.1.3.6.1.4.1.8886.2.1.5.1.1.29
Type
column
Access
readonly
Status
current
Parent
rcftSlotStatEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RAISECOM-RCFT-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-RCFT-MIB::rcftSlotLBKTestOk'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RAISECOM-RCFT-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RAISECOM-RCFT-MIB::rcftSlotLBKTestOk.<rcftChassisIndex>.<rcftSlotIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RAISECOM-RCFT-MIB' -M '/opt/observium/mibs/raisecom:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RAISECOM-RCFT-MIB::rcftSlotLBKTestOk'

Syntax

Enumeration

Values & Constraints

Enumerated Values
1loopbacktestok
2loopbacktestfault