rcErpsHoldOffTime
RAISECOM-ERPS-MIB ·
.1.3.6.1.4.1.8886.6.1.53.1.2.1.15
Object
column
r/w
Unsigned32
When a new defect or more severe defect occurs (new SF), this event will not be reported immediately to protection switching if the provisioned holdoff timer value is non-zero. Instead, the holdoff timer will be started. When the holdoff timer expires, whether a defect still exists on the trail that started the timer will be checked. If one does exist, that defect will be reported to protection switching. Each protection group should have a provisionable holdoff timer. The suggested range of the holdoff timer is 0 to 10 seconds in steps of 100 ms with an accuracy of 5 ms.
Context
- MIB
- RAISECOM-ERPS-MIB
- OID
.1.3.6.1.4.1.8886.6.1.53.1.2.1.15- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- rcErpsCfgEntry
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 0-100