Holds a compressed string of all data per interface.
Compressed Air Interface Structure (size in brackets):
UAS (4), ES (4), SES (4), BBE (4), Integrity (1),
MinRSL (1), MaxRSL (1), RSLThresh1Exceeded (4),
RSLThresh2Exceeded (4), MinTSL (1), MaxTSL (1),
TSLThresh1Exceed (4), BBERThresh1Exceed (4), RxMBytes (4)
TxMBytes (4), EthCapacityThreshUnder (4), HighTrafficThreshExceed (4)
Compressed Etherent ODU interface (size in brackets):
UAS (4), ES (4), SES (4), BBE (4), Integrity (1),
RxMBytes (4), TxMBytes (4), EthCapacityThreshUnder (4),
HighTrafficThreshExceed (4), ActiveSeconds (1)
Context
- MIB
- RADWIN-MIB-WINLINK1000
- OID
.1.3.6.1.4.1.4458.1000.1.6.2.1.7- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- winlink1000OduPerfMonIntervalEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RADWIN-MIB-WINLINK1000' -M '/opt/observium/mibs/radwin:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonIntervalCompressed'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RADWIN-MIB-WINLINK1000' -M '/opt/observium/mibs/radwin:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonIntervalCompressed.<ifIndex>.<winlink1000OduPerfMonIntervalIdx>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RADWIN-MIB-WINLINK1000' -M '/opt/observium/mibs/radwin:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RADWIN-MIB-WINLINK1000::winlink1000OduPerfMonIntervalCompressed'
Syntax
OctetString
Values & Constraints