winlink1000IduTdmMasterClockDesired

RADWIN-MIB-WINLINK1000 · .1.3.6.1.4.1.4458.1000.2.6.2.2

Object

scalar mandatory r/w Enumeration
Required TDM Master Clock. A change is effective after re-activation of the TDM service.

Context

MIB
RADWIN-MIB-WINLINK1000
OID
.1.3.6.1.4.1.4458.1000.2.6.2.2
Type
scalar
Access
readwrite
Status
mandatory
Parent
winlink1000IduTdmMasterClock

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RADWIN-MIB-WINLINK1000' -M '/opt/observium/mibs/radwin:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RADWIN-MIB-WINLINK1000::winlink1000IduTdmMasterClockDesired.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RADWIN-MIB-WINLINK1000' -M '/opt/observium/mibs/radwin:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RADWIN-MIB-WINLINK1000::winlink1000IduTdmMasterClockDesired'

Syntax

Enumeration

Values & Constraints

Enumerated Values
2automatic
4trunk1
8trunk2
16trunk3
32trunk4
64multipleClocks