winlink1000IduSrvEthMaxInfoRate

RADWIN-MIB-WINLINK1000 · .1.3.6.1.4.1.4458.1000.2.2.15

Object

scalar mandatory r/w Integer32
Holds the maximum bandwidth (kbps) to be allocated for Ethernet service.
Value of zero means that Ethernet service works as best effort.
The maximum value is product specific. Refer to the user manual.

Context

MIB
RADWIN-MIB-WINLINK1000
OID
.1.3.6.1.4.1.4458.1000.2.2.15
Type
scalar
Access
readwrite
Status
mandatory
Parent
winlink1000IduService

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RADWIN-MIB-WINLINK1000' -M '/opt/observium/mibs/radwin:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RADWIN-MIB-WINLINK1000::winlink1000IduSrvEthMaxInfoRate.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RADWIN-MIB-WINLINK1000' -M '/opt/observium/mibs/radwin:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RADWIN-MIB-WINLINK1000::winlink1000IduSrvEthMaxInfoRate'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-122880