winlink1000HbsAirCompressedMonSec

RADWIN-MIB-WINLINK1000 · .1.3.6.1.4.1.4458.1000.3.1.19

Object

scalar mandatory RFC1213-MIBDisplayString
One string that holds the 4 Utilization per Sector values:
DownUtil	(2 bytes),
UpUtil  	(2 bytes),
DownTraffic (4 bytes),
UpTraffic 	(4 bytes).

Context

MIB
RADWIN-MIB-WINLINK1000
OID
.1.3.6.1.4.1.4458.1000.3.1.19
Type
scalar
Access
readonly
Status
mandatory
Parent
winlink1000HbsAir

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RADWIN-MIB-WINLINK1000' -M '/opt/observium/mibs/radwin:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RADWIN-MIB-WINLINK1000::winlink1000HbsAirCompressedMonSec.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RADWIN-MIB-WINLINK1000' -M '/opt/observium/mibs/radwin:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RADWIN-MIB-WINLINK1000::winlink1000HbsAirCompressedMonSec'

Syntax

Source
RFC1213-MIBDisplayString
Base type
OctetString

Values & Constraints

No enumerated values or constraints recorded.