rlPimTmEntSsmSrcAndGrpFilter

RADLAN-PIM-MIB · .1.3.6.1.4.1.89.211.6.1.18

Object

When SSM source and group filtering is enabled, then for
groups in the SSM space, the local router will:
              
-  process received PIM (S,G) Join messages only if the
   {source, group} pair is included in the extended access
   list corresponding to the list index value configured for
   this object, and
              
-  accept (S,G) local membership requests from the MGMD
   Router component only if the {source, group} pair is
   included in the extended access list corresponding to the
   list index value configured for this object.
              
In other words, the extended access list is a whitelist of
the SSM {source, group} pairs for which DC-PIM is
permitted to request traffic.
              
rlPimTmEntSsmSrcAndGrpFilter defaults to an empty string,
which indicates that no access list is specified.

Context

MIB
RADLAN-PIM-MIB
OID
.1.3.6.1.4.1.89.211.6.1.18
Type
column
Access
readwrite
Status
current
Parent
rlPimTmEntEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'RADLAN-PIM-MIB' -M '/opt/observium/mibs/radlan:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RADLAN-PIM-MIB::rlPimTmEntSsmSrcAndGrpFilter'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'RADLAN-PIM-MIB' -M '/opt/observium/mibs/radlan:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'RADLAN-PIM-MIB::rlPimTmEntSsmSrcAndGrpFilter.<rlPimTmEntIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'RADLAN-PIM-MIB' -M '/opt/observium/mibs/radlan:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'RADLAN-PIM-MIB::rlPimTmEntSsmSrcAndGrpFilter'

Syntax

Source
SNMPv2-TCDisplayString
Base type
OctetString
Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
          
character set, as defined in pages 4, 10-11 of RFC 854.
          
To summarize RFC 854, the NVT ASCII repertoire specifies:
          
  - the use of character codes 0-127 (decimal)
          
  - the graphics characters (32-126) are interpreted as
    US ASCII
          
  - NUL, LF, CR, BEL, BS, HT, VT and FF have the special
    meanings specified in RFC 854
          
  - the other 25 codes have no standard interpretation
          
  - the sequence 'CR LF' means newline
          
  - the sequence 'CR NUL' means carriage-return
          
  - an 'LF' not preceded by a 'CR' means moving to the
    same column on the next line.
          
  - the sequence 'CR x' for any x other than LF or NUL is
    illegal.  (Note that this also means that a string may
    end with either 'CR LF' or 'CR NUL', but not with CR.)
          
Any object defined using this syntax may not exceed 255
characters in length.

Values & Constraints

Type Constraints
range: 0..255