protectGroupMode
RAD-Protection-MIB ·
.1.3.6.1.4.1.164.6.2.72.1.1.5
Object
column
r/w
Enumeration
This object defines mode of protection that the group uses.
TDM PW protection uses 2 modes:
1. Independent - PW endpoint nodes independently select
which PW they intend to make active and which PW they
intend to make standby.
2. Master/slave - one endpoint node of the redundant set of
PWs is designated the master and is responsible for
selecting which PW both endpoints must use to forward
user traffic. The other endpoint node, the slave, must
follow the decision of the master.
Context
- MIB
- RAD-Protection-MIB
- OID
.1.3.6.1.4.1.164.6.2.72.1.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- protectGroupEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | manual |
2 | onePlusOne |
3 | oneToOne |
4 | oneToOneIndepend |
5 | oneToOneMaster |
6 | oneToOneSlave |