sysCRdnFlipUponEvent
RAD-Dacs-MIB ·
.1.3.6.1.4.1.164.3.3.1.6.3.1.13
Object
column
r/w
Integer32
This object allows user to define if Flip to the other port will be performed (or not), for certain possible events. Each event is represented by a bit. The value of the object is a sum of 2**n, according to the bits having '1' value. '1' - means that Flip should occur due to this event. Bit 0 (LSB) = SD (Signal Degraded). For IPmux: Bit 0 (LSB) = TDM Line LOS/LOF. Bit 1 = Sequence Number. Bit 2 = Jitter Buffer errors.
Context
- MIB
- RAD-Dacs-MIB
- OID
.1.3.6.1.4.1.164.3.3.1.6.3.1.13- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- sysCRdnEntry
Syntax
Integer32
Values & Constraints