prtGenTsIConPrt
RAD-Dacs-MIB ·
.1.3.6.1.4.1.164.3.3.3.1.3.1.5
Object
column
r/w
Integer32
This attribute indicates the internally (In Mux)
connected port.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
* The outside ports will be the T1/E1 cards ports.
The convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
for a stand-alone unit, the IO slot will be considered 1.
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
* The inside ports will be for example, the HS cards ports.
The convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
for a stand-alone unit, the IO slot will be considered 1.
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
* noConnection - will be indicated as 10 for DXC and FCD-E1/T1.
- will be indicated as 100 for FCD-E1/I and SMODs.
* Split TS (same TS is Split to several ports) - 11.
* notApplicable- will be indicated as 100 for LRS IMODs.
All HS port's timeslots must have the same destination
port.
Context
- MIB
- RAD-Dacs-MIB
- OID
.1.3.6.1.4.1.164.3.3.3.1.3.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- prtGenTsEntry
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.