prtGenTestRunningXP
RAD-Dacs-MIB ·
.1.3.6.1.4.1.164.3.3.3.1.1.1.19
Object
column
OctetString
This is an Expanded object of the prtGenTestRunning object.
The prtGenTestRunning object reached its maximum, being an Integer with 31 bits.
This object indicates which tests are running currently on
the selected port (initiated by user and/or by the system).
If a specific test is currently running on the port, its
respective bit will be SET:
TEST BIT
----------- ---
localLoop 1 =LSB
remoteLoop 2
bert 3
plb 4
llb 5
txInband 6
rxInband 7
prbs 8
loop2-v54 (RLB) 9
loop3-v54 (LLB) 10
DDS DSU loop 11
DDS CSU loop 12
Tone injection 13
Tx-plb 14
Tx-llb 15
DTE loop (HSSI) 16
Local DTE loop (HSSI)17
Local Line loop (HSSI)18
Remote Line loop (HSSI)19
HDSL-Tx-Inband 20
HDSL-Rx-Inband 21
Monitor 22 (test port)
User Line Loopback 23
Network Line Loopback 24
Rem-Loop-on-Rem-Unit 25
LBBD 26
LB1 27
LB2 28
BERT-on-Rem-Unit 29
TS Remote Loop 30
LLB-on-Rem-Unit 31
Downstream-AIS 32
Upstream-AIS 33
Send-RDI 34
Test Per TS 35
e.g : If the return value is 00000003 hex ->
Bits 1 & 2 are set -> the running tests are :
local-loop
remote-loop
llb (Bit 5) - can be initiated by system only!