prtGenTestCmdXP
RAD-Dacs-MIB ·
.1.3.6.1.4.1.164.3.3.3.1.1.1.18
Object
column
r/w
OctetString
This is an Expanded test command of the prtGenTestCmd object.
The prtGenTestCmd object reached its maximum, being an Integer with 31 bits.
Setting this object to a value as detailed furter on
(except 0) will initiate a test on the specific port,
if the operation is allowed (according to TestMaskXP).
If the operation is not allowed, the mux will ignore the
operation.
The test/s requested will be set according to the respective
bit:
TEST BIT
----------- ---
localLoop 1 =LSB
remoteLoop 2
bert 3
plb 4
inband 5
prbs 8
loop2-v54 (RLB) 9
loop3-v54 (LLB) 10
Tone injection 13
Tx-plb 14
Tx-llb 15
DTE loop (HSSI) 16
HDSL-Tx-Inband 20
HDSL-Rx-Inband 21
Monitor 22 (test port)
User Line Loopback 23
Rem-Loop-on-Rem-Unit 25
LBBD 26
LB1 27
LB2 28
BERT-on-Rem-Unit 29
TS Remote Loop 30
LLB-on-Rem-Unit 31
Downstream-AIS 32
Upstream-AIS 33
Send-RDI 34
Test Per TS 35
e.g : If the requested value is 00000003 hex ->
Bits 1 & 2 are set -> the requested tests are :
local-loop
remote-loop
Setting this object to stop (value=0 ; all bits are 0),
will stop all the user requested tests running on the
selected port; it will NOT stop the tests initiated by
the system.
Context
- MIB
- RAD-Dacs-MIB
- OID
.1.3.6.1.4.1.164.3.3.3.1.1.1.18- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- prtGenEntry
Syntax
OctetString
Values & Constraints
No enumerated values or constraints recorded.