mdlCFanControl
RAD-Dacs-MIB ·
.1.3.6.1.4.1.164.3.3.2.1.2.1.22
Object
column
r/w
Enumeration
The desired state of the fan.
Module fan control shall manage all fans on the module, if there are more than one.
When mdlCFanControl is 'up', all module's fans must be in on state.
When mdlCFanControl is 'down', all module's fans must be in off state.
Setting module mdlCFanControl to 'up' should always succeed (if HW enables detection of
current fan status, the mdlCFanStatus might remain 'down' as a result of a fan failure).
up
The desired state for all module's fans is operational.
down
The desired state for all module's fans is disabled.
Context
- MIB
- RAD-Dacs-MIB
- OID
.1.3.6.1.4.1.164.3.3.2.1.2.1.22- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- mdlCEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | up |
2 | down |