pmPolicyActionMaxLatency
POLICY-BASED-MANAGEMENT-MIB ·
.1.3.6.1.2.1.124.1.1.11
Object
column
r/w
milliseconds Unsigned32
Every element that matches this policy's condition and is
therefore under control of this policy will have this policy's
action executed periodically to ensure that the element
remains in the state dictated by the policy.
This object lets the manager control the maximum amount of
time that may pass before an element has the action run on
it.
In other words, in any given interval of this duration, all
elements under control of this policy must have the action run
on them. Note that how the policy agent schedules the policy
action on various elements within this interval is an
implementation-dependent matter.
Context
- MIB
- POLICY-BASED-MANAGEMENT-MIB
- OID
.1.3.6.1.2.1.124.1.1.11- Type
- column
- Access
- readwrite
- Status
- current
- Units
- milliseconds
- Parent
- pmPolicyEntry
Syntax
milliseconds Unsigned32
Values & Constraints
Object Constraints
range: 0-2147483647