pimInterfaceElectionNotificationPeriod

PIM-STD-MIB · .1.3.6.1.2.1.157.1.45

Object

scalar r/w seconds Unsigned32
The minimum time that must elapse between
pimInterfaceElection notifications originated by this
router.  The default value of 65535 represents an 'infinite'
time, in which case, no pimInterfaceElection notifications
are ever sent.
          
The storage type of this object is determined by
pimDeviceConfigStorageType.

Context

MIB
PIM-STD-MIB
OID
.1.3.6.1.2.1.157.1.45
Type
scalar
Access
readwrite
Status
current
Units
seconds
Parent
pim
Siblings
47

Syntax

seconds Unsigned32

Values & Constraints

Object Constraints
range: 0-65535

Related Objects