reliabilityId
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.10.1.2.1.2
Object
column SNMPv2-TCDisplayString
Unique ID of the entry.
POH
Power on hours.
CB.<label>.TRIPCNT
Trip count of circuit breaker with label <label>.
CTRL.<serial>.<addr>.MAIN.CSUMERRLASTHOUR
Number of checksum errors in sub (controller board) to main (CPU
board) communication in the last hour on controller with serial
number <serial> and bus address <addr>.
CTRL.<serial>.<addr>.SUB.CSUMERRLASTHOUR
Number of checksum errors in main (CPU board) to sub (controller
board) communication in the last hour on controller with serial
number <serial> and bus address <addr>.
CTRL.<serial>.<addr>.TOUTLASTHOUR
Number of communication timeouts to controller with serial
number <serial> and bus address <addr> in the last hour.
CTRL.<serial>.<addr>.RLY.<num>.CYCLECNT
Number of cycles the relay <num> on the controller board with serial
number <serial> and bus address <addr> has made. A cycle is an
off->on followed by an on->off event later. The count is increased on
the off->on transition.
CTRL.<serial>.<addr>.RLY.<num>.FAILLASTHOUR
Number of failed switching operations on relay <num> on the controller
board with serial number <serial> and bus address <addr> in the last
hour. It depends on the specific controller board hardware and what
error conditions are detected.
CTRL.<serial>.<addr>.EMRSTCNT
Number of energy-meter resets on the controller board with serial
number <serial> and bus address <addr>.
CTRL.<serial>.<addr>.RSTCNT
Number of resets of the controller board with serial number <serial>
and bus address <addr>.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.10.1.2.1.2- Type
- column
- Access
- readonly
- Status
- current
- Parent
- reliabilityDataEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'PDU2-MIB' -M '/opt/observium/mibs/raritan:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PDU2-MIB::reliabilityId'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'PDU2-MIB' -M '/opt/observium/mibs/raritan:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'PDU2-MIB::reliabilityId.<reliabilityIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'PDU2-MIB' -M '/opt/observium/mibs/raritan:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'PDU2-MIB::reliabilityId'
Syntax
- Source
- SNMPv2-TCDisplayString
- Base type
OctetString- Display format
255a
Type Description
Represents textual information taken from the NVT ASCII
character set, as defined in pages 4, 10-11 of RFC 854.
To summarize RFC 854, the NVT ASCII repertoire specifies:
- the use of character codes 0-127 (decimal)
- the graphics characters (32-126) are interpreted as
US ASCII
- NUL, LF, CR, BEL, BS, HT, VT and FF have the special
meanings specified in RFC 854
- the other 25 codes have no standard interpretation
- the sequence 'CR LF' means newline
- the sequence 'CR NUL' means carriage-return
- an 'LF' not preceded by a 'CR' means moving to the
same column on the next line.
- the sequence 'CR x' for any x other than LF or NUL is
illegal. (Note that this also means that a string may
end with either 'CR LF' or 'CR NUL', but not with CR.)
Any object defined using this syntax may not exceed 255
characters in length.
Values & Constraints
Type Constraints
range: 0..255
Conformance
Member of