optixRtnIFATPCLowThreshold
OPTIX-RTN-ATPC-MGR-MIB ·
.1.3.6.1.4.1.2011.2.25.4.40.1.10.1.1.4
Object
column
r/w
Integer32
Indicates the ATPC adjustment lower threshold. When the RSL is less than the lower threshold, the transmitter automatically adjusts its transmit power. Signed int type Value range: -900.0 to -250.0 Unit: 0.1 dBm
Context
- MIB
- OPTIX-RTN-ATPC-MGR-MIB
- OID
.1.3.6.1.4.1.2011.2.25.4.40.1.10.1.1.4- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- optixRtnIFATPCParameterEntry
Syntax
Integer32
Values & Constraints
No enumerated values or constraints recorded.