oacAAATacacsServerPort

ONEACCESS-AAA-MIB · .1.3.6.1.4.1.13191.10.3.4.10.1.3.1.2

Object

column r/w Integer32
The default for an tacacs client to connect to tacacs server
is 49. But this can vary depending on the server configuration.
Hence when a tacacs server is added the port on which this server
is running has to be specified.

Context

MIB
ONEACCESS-AAA-MIB
OID
.1.3.6.1.4.1.13191.10.3.4.10.1.3.1.2
Type
column
Access
readwrite
Status
current
Default
49
Parent
oacAAATacacsServerConfigEntry

Walk the column to discover its indexed instances, or supply every index to read one instance.

Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ONEACCESS-AAA-MIB' -M '/opt/observium/mibs/oneaccess:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ONEACCESS-AAA-MIB::oacAAATacacsServerPort'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ONEACCESS-AAA-MIB' -M '/opt/observium/mibs/oneaccess:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ONEACCESS-AAA-MIB::oacAAATacacsServerPort.<oacAAATacacsServerInfo>.<oacAAATacacsServerPort>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ONEACCESS-AAA-MIB' -M '/opt/observium/mibs/oneaccess:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ONEACCESS-AAA-MIB::oacAAATacacsServerPort'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-65535