ostHighCapacityRmonGlobalCfgInterval

OMNITRON-HC-RMON-MIB · .1.3.6.1.4.1.7342.23.1.3

Object

scalar r/w SecondsUnsigned32
This object specifies the interval in seconds over which the data
is sampled for each bucket for each port. 
          
This interval can be set to any number of seconds from 1 to 3600
(1 hour). The default value is 900s or 15min.

Context

MIB
OMNITRON-HC-RMON-MIB
OID
.1.3.6.1.4.1.7342.23.1.3
Type
scalar
Access
readwrite
Status
current
Units
Seconds
Parent
ostHighCapacityRmonGlobalCfgTable
Groups
1

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'OMNITRON-HC-RMON-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'OMNITRON-HC-RMON-MIB::ostHighCapacityRmonGlobalCfgInterval.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'OMNITRON-HC-RMON-MIB' -M '/opt/observium/mibs/omnitron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'OMNITRON-HC-RMON-MIB::ostHighCapacityRmonGlobalCfgInterval'

Syntax

SecondsUnsigned32

Values & Constraints

Object Constraints
range: 60-3600

Conformance