olsrv2RxHoldTime
OLSRv2-MIB ·
.1.3.6.1.2.1.219.1.1.10
Object
scalar
r/w
milliseconds Unsigned32
olsrv2RxHoldTime corresponds to
RX_HOLD_TIME of OLSRv2 and represents the period
after receipt of a message by the appropriate OLSRv2
interface of this router for which that information
is recorded, in order that the message is recognized
as having been previously received on this OLSRv2
interface.
Guidance for setting this object may be found
in Section 5 of the OLSRv2 specification (RFC 7181),
which indicates that:
o olsrv2RxHoldTime > 0
o This parameter SHOULD be greater
than the maximum difference in time that a
message may take to traverse the MANET,
taking into account any message forwarding
jitter as well as propagation, queuing,
and processing delays.
This object is persistent, and when written,
the entity SHOULD save the change to
non-volatile storage.
Context
- MIB
- OLSRv2-MIB
- OID
.1.3.6.1.2.1.219.1.1.10- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- milliseconds
- Parent
- olsrv2ConfigurationGroup
Syntax
milliseconds Unsigned32
Values & Constraints
No enumerated values or constraints recorded.