olsrv2PHoldTime

OLSRv2-MIB · .1.3.6.1.2.1.219.1.1.11

Object

scalar r/w milliseconds Unsigned32
olsrv2PHoldTime corresponds to
P_HOLD_TIME of OLSRv2 and represents the period
after receipt of a message that is processed by
this router for which that information is recorded,
in order that the message is not processed again
if received again.
          
Guidance for setting this object may be found
in Section 5 of the OLSRv2 specification (RFC 7181),
which indicates that:
   o olsrv2PHoldTime > 0
   o This parameter SHOULD be greater
     than the maximum difference in time that a
     message may take to traverse the MANET,
     taking into account any message forwarding
     jitter as well as propagation, queuing,
     and processing delays.
          
This object is persistent, and when written,
the entity SHOULD save the change to
non-volatile storage.

Context

MIB
OLSRv2-MIB
OID
.1.3.6.1.2.1.219.1.1.11
Type
scalar
Access
readwrite
Status
current
Units
milliseconds
Parent
olsrv2ConfigurationGroup

Syntax

milliseconds Unsigned32

Values & Constraints