olsrv2AHoldTime
OLSRv2-MIB ·
.1.3.6.1.2.1.219.1.1.9
Object
scalar
r/w
milliseconds Olsrv2TimeValueCompressedForm32TC
olsrv2AHoldTime corresponds to
A_HOLD_TIME of OLSRv2 and represents
the period during which TC messages are sent
after they no longer have any advertised
information to report, but are sent in order
to accelerate outdated information removal by other
routers.
Guidance for setting this object may be found
in Section 5 of the OLSRv2 specification (RFC 7181),
which indicates that:
o If TC messages can be lost, then
olsrv2AHoldTime SHOULD be
significantly greater than olsrv2TcInterval;
a value >= 3 x olsrv2TcInterval is
RECOMMENDED.
This object is persistent, and when written,
the entity SHOULD save the change to
non-volatile storage.
Context
- MIB
- OLSRv2-MIB
- OID
.1.3.6.1.2.1.219.1.1.9- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- milliseconds
- Parent
- olsrv2ConfigurationGroup
Syntax
milliseconds Olsrv2TimeValueCompressedForm32TC
Values & Constraints
No enumerated values or constraints recorded.