nhdpHHoldTime

NHDP-MIB · .1.3.6.1.2.1.213.1.1.1.1.8

Object

column r/w milliseconds Unsigned32
nhdpHHoldTime corresponds to
H_HOLD_TIME of NHDP and is used as the value
in the VALIDITY_TIME Message TLV included in all
HELLO messages on this MANET interface.  It is then
used by each router receiving such a HELLO message
to indicate the validity of the information taken
from that HELLO message and recorded in the receiving
router's Information Bases.
              
Guidance for setting this object may be found
in Section 5 of the NHDP specification (RFC 6130),
which indicates that it should be assigned a
value significantly greater than the refresh interval
held by nhdpRefreshInterval and must be representable
as described in RFC 5497.

Context

MIB
NHDP-MIB
OID
.1.3.6.1.2.1.213.1.1.1.1.8
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
nhdpInterfaceEntry

Syntax

milliseconds Unsigned32

Values & Constraints

No enumerated values or constraints recorded.